Electromagnetic
Connector Signal-Integrity Vector Field
Adjust copper conductivity on the fixed three-dimensional connector geometry to predict electric- and magnetic-field magnitudes.
Published scope
The inputs, geometry and outputs below follow the registered public case. Published verification applies only to the stated conditions. Service availability requires a live request.
Frequency-Domain Vector Direct Parametric MLP
Conductors and insulators in a connector shape its electromagnetic field, while operating frequency and material parameters affect local field strength.
The case predicts the connector's three-dimensional electromagnetic vector field and reveals internal distributions and high-field regions.
- Geometry
- Imported complex connector geometry
- Geometry scope
- same_geometry_only
Adjustable inputs
| Input | Range | Default |
|---|---|---|
| Copper conductivity | 55100000.0 – 58000000.0 S/m | 55100000.0 |
Output fields
- 电磁矢量场: Electric Field Magnitude, Magnetic Field Magnitude
Registered verification
- registered_status
- failed
- summary
- The registered 55.1 MS/m holdout did not pass the Relative L2 threshold.
- holdout_parameters
- conductor_sigma: 55100000.0
- holdout_metrics
- RMSE: 705.662; Relative L2: 0.513296; Correlation: 0.857994
- thresholds
- max_rmse: 5000.0; max_relative_l2: 0.4; min_correlation: 0.8
Recorded workflow evidence
- Project opening
- PASS
- Save and reopen
- PASS
- Training
- BLOCKED_MISSING_REFERENCE_CSV
- Prediction
- PASS_EXISTING_SAVED_MODEL
- Independent accuracy
- FAIL
- Portable validation
- NOT_RUN
These are recorded checks; they do not establish live service availability or accuracy for every new request.